Bacteria: Gram-negative

Legionella species

Legionella pneumophila; Legionella longbeachae

General medical information for education only, not medical advice. Treatment considerations summarize published guidance at drug-class level; therapy is chosen by the treating clinician using susceptibility results, local resistance patterns and current guidelines.

Overview

Gram-negative rods from water systems (L. pneumophila) or soil and potting mix (L. longbeachae), acquired by inhaling contaminated aerosols or dust.

Infections

Legionnaires' disease (pneumonia) and Pontiac fever (a milder flu-like illness).

Signs and symptoms

High fever, cough, shortness of breath, muscle aches, headache, diarrhea; low sodium is common.

Antibiotic and antimicrobial resistance

Clinically relevant resistance is uncommon.

Treatment considerations

Azithromycin or a respiratory fluoroquinolone (levofloxacin). Beta-lactams are ineffective.

Infection control and public health

Nationally notifiable; a healthcare-associated case should prompt investigation of the facility water system.

Rod-shaped Legionella pneumophila bacteria, colorized scanning electron micrograph
Legionella pneumophila, scanning electron micrograph (colorized). CDC (J. H. Carr); public domain. Image source
Gram-negative rods, schematic
Gram-negative rods. Schematic, not to scale; InnovexLab.

Sources

  1. CDC. Legionnaires' disease.
  2. ATS / IDSA. Community-Acquired Pneumonia in Adults guideline.

Sources accessed November 2026. Links open external sites that InnovexLab does not control.

Medical disclaimer

This page is general educational information summarized from published public-health and professional-society guidance. It is not medical advice, a diagnosis or a treatment recommendation, and reading it does not create a clinician–patient relationship with InnovexLab. Decisions about testing, diagnosis and treatment belong to the treating clinician, using the patient’s history and examination, laboratory and susceptibility results, local resistance patterns and current guidelines. Guidance changes over time; consult the original sources for the latest version. InnovexLab provides this information as is and does not warrant that it is complete or current.

Patients with questions about their health should contact their own healthcare provider. In an emergency, call 911.

Sources, image credits and editorial policy

Discuss a testing program with InnovexLab

Review the panel that fits your patients, its specimen requirements, and how results and billing work.